z/OS TADz for ACF2 Security Technical Implementation Guide
Pick two releases to diff their requirements.
Open a previous version of this STIG.
Digest of Updates ✎ 3
Comparison against the immediately-prior release (V7R1). Rule matching uses the Group Vuln ID. Content-change detection compares the rule’s description, check, and fix text after stripping inline markup — cosmetic-only edits aren’t flagged.
Content changes 3
- V-224344 Medium descriptioncheckfix Tivoli Asset Discovery for z/OS (TADz) Install datasets are not properly protected.
- V-224345 Medium descriptioncheckfix Tivoli Asset Discovery for zOS (TADz) STC and/or batch datasets are not properly protected.
- V-224346 Medium checkfix Tivoli Asset Discovery for z/OS (TADz) Started Task name(s) must be properly identified / defined to the system ACP.
- RMF Control
- CM-5
- Severity
- M
- CCI
- CCI-001499
- Version
- ZTADA000
- Vuln IDs
-
- V-224344
- V-16932
- Rule IDs
-
- SV-224344r1141645_rule
- SV-28469
Checks: C-26021r1141643_chk
Refer to the following report produced by the dataset and Resource Data Collection: - SENSITVE.RPT(TADZRPT). Automated Analysis Refer to the following report produced by the dataset and Resource Data Collection: - PDI(ZTAD0000). Verify that access to the TADz Install datasets is properly restricted. If the following guidance is true, this is not a finding. The ACF2 dataset rules for the datasets restrict WRITE and/or greater access to systems programming personnel. The ACF2 dataset rules for the datasets do not specify that all (i.e., failures and successes) WRITE and/or greater access will be logged.
Fix: F-26009r1141644_fix
The ISSO will ensure that WRITE and/or greater access to program product datasets is limited to systems programmers only, and all WRITE and/or greater access is logged. Auditors should have READ access. The installing systems programmer will identify and document the product datasets, categorize them according to who will have WRITE and/or greater access, and if required, ensure that all WRITE and/or greater access is logged. The installing systems programmer will identify if any additional groups have UPDATE access for specific datasets, and once documented, will work with the ISSO to ensure they are properly restricted to the Access Control Program (ACP) active on the system. Datasets to be protected will be: SYS2.TADZ SYS2.TADZ .V-.SHSIMOD1 SYS3.TADZ The following commands are provided as a sample for implementing dataset controls: $KEY(SYS2) TADZ.- UID(syspaudt) R(A) W(L) A(L) E(A) TADZ.V-.SHSIMOD1 UID(syspaudt) R(A) W(L) A(L) E(A) TADZ.- UID(audtaudt) R(A) E(A) $KEY(SYS3) TADZ.- UID(syspaudt) R(A) W(L) A(L) E(A) TADZ.- UID(audtaudt) R(A) E(A)
- RMF Control
- CM-5
- Severity
- M
- CCI
- CCI-001499
- Version
- ZTADA001
- Vuln IDs
-
- V-224345
- V-17067
- Rule IDs
-
- SV-224345r1141648_rule
- SV-28547
Checks: C-26022r1141646_chk
Refer to the following report produced by the dataset and Resource Data Collection: - SENSITVE.RPT(TADZSTC). Automated Analysis Refer to the following report produced by the dataset and Resource Data Collection: - PDI(ZTAD0001). Verify that access to the TADz STC and/or batch datasets are properly restricted. If the following guidance is true, this is not a finding. The ACF2 dataset rules for the datasets restrict WRITE and/or greater access to systems programming personnel and the product STC(s) and/or batch job(s). The ACF2 dataset rules for the datasets restrict READ access to job scheduling products. The ACF2 dataset rules for the datasets restrict READ access to auditors.
Fix: F-26010r1141647_fix
Grant WRITE and/or greater access to Tivoli Asset Discovery for z/OS (TADz) STC and/or batch datasets are limited to systems programmers and TADz STC and/or batch jobs only. Grant READ access to any scheduling products that are in use. Grant READ access to auditors at the ISSO's discretion. Identify and document the product datasets and categorize them according to who will have WRITE and/or greater access and, if required, that all WRITE and/or greater access is logged. Identify if any additional groups have UPDATE access for specific datasets, and assure that they are properly restricted to the ACP (Access Control Program) active on the system. Datasets to be protected will be: SYS3.TADZ The following commands are provided as a sample for implementing dataset controls: $KEY(SYS3) TADZ.- UID(syspaudt) R(A) W(A) A(A) E(A) TADZ.- UID(audtaudt) R(A) E(A) TADZ.-.UM.- UID(batchid TADZINQ) R(A) W(A) A(A) E(A) TADZ.-.IQ.- UID(batchid TADZINQ) R(A) W(A) A(A) E(A) TADZ.-.UIQ.- UID(batchid TADZINQ) R(A) W(A) A(A) E(A) TADZ.- UID(stc id TADZMON) R(A) W(A) A(A) E(A)
- RMF Control
- IA-2
- Severity
- M
- CCI
- CCI-000764
- Version
- ZTADA030
- Vuln IDs
-
- V-224346
- V-17452
- Rule IDs
-
- SV-224346r1141651_rule
- SV-28612
Checks: C-26023r1141649_chk
Refer to the following report produced by the ACF2 Data Collection: - ACF2CMDS.RPT(LOGONIDS). Verify that the logonid(s) for the TADz started task(s) is (are) properly defined. If the following attributes are defined, this is not a finding. For each STC logonid: STC For each Batch logonid: JOB
Fix: F-26011r1141650_fix
The TADz systems programmer and the ISSO will ensure that a product's Started Task(s) is properly identified / defined to the System ACP. If the product requires a Started Task, verify that it is properly defined to the System ACP with the proper attributes. Most installation manuals will indicate how the Started Task is identified and any additional attributes that must be specified. Example: SET LID CHANGE TADZMON STC