Select any two versions of this STIG to compare the individual requirements
Select any old version/release of this STIG to view the previous requirements
a) Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(TADZRPT) Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZTAD0000) b) Verify that access to the TADz Install data sets are properly restricted. ___ The ACF2 data set rules for the data sets does not restrict UPDATE and/or ALTER access to systems programming personnel. ___ The ACF2 data set rules for the data sets does not specify that all (i.e., failures and successes) UPDATE and/or ALTER access will be logged. c) If all of the above are untrue, there is NO FINDING. d) If any of the above is true, this is a FINDING.
The IAO will ensure that update and allocate access to program product data sets is limited to System Programmers only, and all update and allocate access is logged. Auditors should have read access. The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. He will identify if any additional groups have update access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program ) active on the system. Data sets to be protected will be: SYS2.TADZ SYS2.TADZ .V-.SHSIMOD1 SYS3.TADZ The following commands are provided as a sample for implementing dataset controls: $KEY(SYS2) TADZ.- UID(syspaudt) R(A) W(L) A(L) E(A) TADZ.V-.SHSIMOD1 UID(syspaudt) R(A) W(L) A(L) E(A) TADZ.- UID(audtaudt) R(A) E(A) $KEY(SYS3) TADZ.- UID(syspaudt) R(A) W(L) A(L) E(A) TADZ.- UID(audtaudt) R(A) E(A)
Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(TADZSTC) Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZTAD0001) For all (TADz) STC and/or batch data sets: If the UPDATE or greater access is restricted to systems programming personnel and the product STC(s) and/or batch job(s) this is not a finding. If any job scheduling products are in use and access is restricted to READ this is not a finding. If auditors have READ access this is not a finding.
Grant update and alter access to Tivoli Asset Discovery for z/OS (TADz) STC and/or batch data sets are limited to system programmers and TADz STC and/or batch jobs only. Grant read access to any scheduling products that are in use. Grant read access to auditors at the ISSO's discretion. Identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. Identify if any additional groups have update access for specific data sets, and assure that they are properly restricted to the ACP (Access Control Program) active on the system. Data sets to be protected will be: SYS3.TADZ The following commands are provided as a sample for implementing dataset controls: $KEY(SYS3) TADZ.- UID(syspaudt) R(A) W(A) A(A) E(A) TADZ.- UID(audtaudt) R(A) E(A) TADZ.-.UM.- UID(batchid TADZINQ) R(A) W(A) A(A) E(A) TADZ.-.IQ.- UID(batchid TADZINQ) R(A) W(A) A(A) E(A) TADZ.-.UIQ.- UID(batchid TADZINQ) R(A) W(A) A(A) E(A) TADZ.- UID(stc id TADZMON) R(A) W(A) A(A) E(A)
Refer to the following report produced by the ACF2 Data Collection: - ACF2CMDS.RPT(LOGONIDS) Ensure the following field is completed for each STC logonid for the product: STC Ensure the following field is completed for each Batch logonid for the product: JOB If the logonids specified in (b) and/or (c) have all the required field is completed, this is not a FINDING. If the logonids specified in (b) and/or (c) do not have the above field completed, this is a FINDING.
The TADz system programmer and the ISSO will ensure that a product's Started Task(s) is properly identified / defined to the System ACP. If the product requires a Started Task, verify that it is properly defined to the System ACP with the proper attributes. Most installation manuals will indicate how the Started Task is identified and any additional attributes that must be specified. Example: SET LID CHANGE TADZMON STC