Select any two versions of this STIG to compare the individual requirements
Select any old version/release of this STIG to view the previous requirements
Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(ROSRPT). Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZROS0000). Verify that access to the ROSCOE Install data set are properly restricted. If the following guidance is true, this is not a finding. The RACF data set rules for the data sets restrict WRITE and/or greater access to systems programming personnel. The RACF data set rules for the data sets specify that all (i.e., failures and successes) WRITE and/or greater access will be logged.
The ISSO will ensure that WRITE and/or greater access to program product data sets is limited to system programmers, security personnel and auditors only, and all WRITE and/or greater access is logged. The installing systems programmer will identify and document the product data sets and categorize them according to who will have WRITE and/or greater access and if required that all WRITE and/or greater access is logged. The installing systems programmer will identify if any additional groups have UPDATE access for specific data sets, and once documented, will work with the ISSO to ensure they are properly restricted to the Access Control Program (ACP) active on the system. Data set prefix to be protected will be: SYS2.ROSCOE. SYS2A.ROSCOE. SYS3.ROSCOE. SYS3A.ROSCOE. The following commands are provided as a sample for implementing data set controls: ad 'sys2.roscoe.**' uacc(none) owner(sys2) - audit(success(update) failures(read)) - data('Vendor DS Profile: ROSCOE') pe 'sys2.roscoe.**' id(syspaudt) acc(a) pe 'sys2.roscoe.**' id(*) acc(r) ad 'sys2a.roscoe.**' uacc(none) owner(sys2a) - audit(success(update) failures(read)) - data('Roscoe Vendor Datasets') pe 'sys2a.roscoe.**' id(<syspaudt>) acc(a) pe 'sys2a.roscoe.**' id(*) acc(r) ad 'sys3.roscoe.**' uacc(none) owner(sys3) - audit(success(update) failures(read)) - data('Roscoe Vendor Datasets') pe 'sys3.roscoe.**' id(<syspaudt>) acc(a) pe 'sys3.roscoe.**' id(*) acc(r) ad 'sys3a.roscoe.**' uacc(none) owner(sys3a) - audit(success(update) failures(read)) - data('Roscoe Vendor Datasets') pe 'sys3a.roscoe.**' id(<syspaudt>) acc(a) pe 'sys3a.roscoe.**' id(*) acc(r) setr generic(dataset) refresh
Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(ROSSTC). Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZROS0001). Verify that access to the ROSCOE STC data sets is properly restricted. The data sets in this group are the data sets identified in the ROSACTxx (if used), ROSLIBxx, and SYSAWSx DD statements of the STC or batch JCL. If the following guidance is true, this is not a finding. The RACF data set rules for the data sets restrict WRITE and/or greater access to systems programming personnel. The RACF data set rules for the data sets restrict WRITE and/or greater access to the product STC(s) and/or batch job(s).
The ISSO will ensure that WRITE and/or greater access to the ROSCOE started task or batch job data sets is limited to system programmers and the started task only and all WRITE and/or greater access is logged. The ISSO will ensure that all other accesses to the ROSCOE started task or batch job data sets are properly restricted and all required accesses are properly logged. Data sets to be protected will be: SYS3.ROSCOE.sys*.** SYS3.ROSCOE.ros*.** The following commands are provided as a sample for implementing data set controls: ad 'sys3.roscoe.ros*.**' uacc(none) owner(sys3) - audit(success(update) failures(read)) - data('Site Customized Profile: ROSCOE') pe 'sys3.roscoe.ros*.**' id(syspaudt) acc(a) pe 'sys3.roscoe.ros*.**' id(roscoe) acc(a) ad 'sys3.roscoe.sys*.**' uacc(none) owner(sys3) - audit(success(update) failures(read)) - data('Site Customized profile: ROSCOE') pe 'sys3.roscoe.sys*.**' id(syspaudt) acc(a) pe 'sys3.roscoe.sys*.**' id(roscoe) acc(a) setr generic(dataset) refresh
Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(ZROS0020). Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZROS0020). Verify all ROSCOE resources and/or generic equivalent are properly protected according to the requirements specified in the CA ROSCOE Resources table in the z/OS STIG Addendum. Note: Wherever an access or user group is missing, use the Site Security Plan (SSP) to determine access and/or user group. If the following guidance is true, this is not a finding. The RACF resource access authorizations restrict access to the appropriate personnel. The RACF resource logging is correctly specified. The RACF resource access authorizations are defined with UACC(NONE) and NOWARNING.
The ISSO will work with the systems programmer to verify that the following are properly specified in the Access Control Program (ACP). (Note: The resources and/or resource prefixes identified below are examples of a possible installation. The actual resources and/or resource prefixes are determined when the product is actually installed on a system through the product's installation guide and can be site specific.) Ensure that all ROSCOE resources and/or generic equivalent are properly protected according to the requirements specified in CA ROSCOE Resources table in the z/OS STIG Addendum. Use CA ROSCOE Resources table in the z/OS STIG Addendum. This table lists the resources, access requirements, and logging requirements for ROSCOE ensure the following guidelines are followed: The RACF resource access authorizations restrict access to the appropriate personnel. The RACF resource logging is correctly specified. The RACF resource access authorizations specify UACC(NONE) and NOWARNING. The following commands are provided as a sample for implementing resource controls: RDEFINE RO@RES rosid.** UACC(NONE) OWNER(ADMIN) AUDIT(FAILURE(READ)) RDEFINE RO@RES rosid.ROSCMD.** UACC(NONE) OWNER(ADMIN) AUDIT(FAILURE(READ)) RDEFINE RO@RES rosid.ROSCMD.MONITOR.** UACC(NONE) OWNER(ADMIN) AUDIT(FAILURE(READ)) RDEFINE RO@RES rosid.ROSCMD.ETSO UACC(NONE) OWNER(ADMIN) AUDIT(FAILURE(READ)) RDEFINE RO@RES rosid.ROSCMD.MONITOR.AMS UACC(NONE) OWNER(ADMIN) AUDIT(FAILURE(READ)) PE rosid.ROSCMD.ETSO CLASS(RO@RES) ID(*) ACCESS(READ) PE rosid.ROSCMD.MONITOR.- CLASS(RO@RES) ID(syspaudt) ACCESS(ALTER) PE rosid.ROSCMD.MONITOR.AMS CLASS(RO@RES) ID(syspaudt) ACCESS(ALTER) PE rosid.ROSCMD.MONITOR.AMS CLASS(RO@RES) ID(*) ACCESS(READ) PE rosid.ROSCMD.- CLASS(RO@RES) ID(syspaudt) ACCESS(ALTER)
Refer to the following report produced by the RACF Data Collection: - RACFCMDS.RPT(LISTUSER). Verify that the userid(s) for the ROSCOE started task(s) is (are) properly defined. If the following attributes are defined, this is not a finding. PROTECTED
The ROSCOE system programmer and the ISSO will ensure that a product's Started Task(s) is properly Identified/defined to the System ACP. If the product requires a Started Task, verify that it is properly defined to the System ACP with the proper attributes. Most installation manuals will indicate how the Started Task is identified and any additional attributes that must be specified. A sample is provided here: au roscoe name('stc, roscoe') owner(stc) dfltgrp(stc) nopass
Refer to the following report produced by the RACF Data Collection: - DSMON.RPT(RACSPT). Automated Analysis Refer to the following report produced by the RACF Data Collection: - PDI(ZROS0032). Verify that the ROSCOE started task(s) is (are) defined to the STARTED resource class profile and/or ICHRIN03 table entry, this is not a finding.
The ROSCOE system programmer and the ISSO will ensure that a product's started task(s) is (are) properly identified and/or defined to the System ACP. A unique userid must be assigned for the ROSCOE started task(s) thru a corresponding STARTED class entry. The following sample set of commands is shown here as a guideline: rdef started ROSCOE.** uacc(none) owner(admin) audit(all(read)) stdata(user(ROSCOE) group(stc)) setr racl(started) ref
Refer to the following report produced by the RACF Data Collection: - RACFCMDS.RPT(SETROPTS). - DSMON.RPT(RACCDT) - Alternate list of active resource classes. Automated Analysis Refer to the following report produced by the RACF Data Collection: - PDI(ZROS0038). If the ROSCOE resource class(es) is (are) active, this is not a finding.
The ISSO will ensure that the Product Resource Class(es) is (are) active. Issue the following commands: SETR CLASSACT(RO@RES) SETR GENERIC(RO@RES)
Have the products system programmer display the configuration/parameters control statements used in the current running product to define or enable security. This information is located in the SYSIN DD statement in the JCL of the STC/Batch job. Automated Analysis Refer to the following report produced by the z/OS Data Collection: - PDI(ZROS0040). If the following keywords specify the values in the ROSCOE configuration/parameter control member, this is not a finding. Keyword Value EXTSEC RACF ACFEXT YES CLLEXT YES JOBEXT YES LIBEXT YES MONEXT YES PRVEXT YES RPFEXT YES UPSEXT YES
The product systems programmer will verify that any configuration/parameters required to control the security of the product are properly configured and syntactically correct. See the required parameters below: Example Keyword Value EXTSEC RACF ACFEXT YES CLLEXT YES JOBEXT YES LIBEXT YES MONEXT YES PRVEXT YES RPFEXT YES UPSEXT YES