Select any two versions of this STIG to compare the individual requirements
Select any old version/release of this STIG to view the previous requirements
Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(MICSRPT) Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZMIC0000) Verify that the accesses to the CA MICS Resource Management installation data sets are properly restricted. If the following guidance is true, this is not a finding. ___ The RACF data set access authorizations restrict READ access to all authorized users (e.g., auditors, security administrators, and MICS end users). ___ The RACF data set access authorizations restrict WRITE and/or greater access to systems programming personnel. ___ The RACF data set access authorizations restrict WRITE and/or greater access to MICS administrators. ___ The RACF data set access authorizations specify that all (i.e., failures and successes) WRITE and/or greater accesses are logged. ___ The RACF data set access authorizations specify UACC(NONE) and NOWARNING.
The IAO will ensure WRITE and/or greater access to CA MICS Resource Management installation data sets is limited to System Programmers and MICS administrators. READ access can be given to all authorized users (e.g., auditors, security administrators, and MICS end users). All failures and successful WRITE and/or greater accesses are logged. The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have WRITE and/or greater access and, if required, that all WRITE and/or greater access is logged. He will identify if any additional groups have WRITE and/or greater access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system. (Note: The data sets and/or data set prefixes identified below are examples of a possible installation. The actual data sets and/or prefixes are determined when the product is actually installed on a system through the product’s installation guide and can be site specific.) Data sets to be protected will be: SYS2.MICS. The following commands are provided as a sample for implementing data set controls: ad 'SYS2.MICS.**' uacc(none) owner(sys2) - audit(success(update) failures(read)) - data('CA-MICS Resource Management Install DS') pe 'SYS2.MICS.**' id(syspaudt tstcaudt micsadm) acc(a) pe 'SYS2.MICS.**' id(audtaudt micsuser secaaudt) acc(r) setr generic(dataset) refresh
Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(MICSUSER) Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZMIC0002) Verify that the accesses to the CA MICS Resource Management User data sets are properly restricted. If the following guidance is true, this is not a finding. ___ The RACF data set access authorizations restrict READ access to all authorized users (e.g., auditors, security administrators, and MICS end users). ___ The RACF data set access authorizations restrict WRITE and/or greater access to systems programming personnel. ___ The RACF data set access authorizations restrict WRITE and/or greater access to SMF Batch user(s) and MICS Administrators. ___ The RACF data set access authorizations for the data sets specify UACC(NONE) and NOWARNING.
The IAO will ensure WRITE and/or greater access to CA MICS Resource Management User data sets is limited to SMF Batch user(s), MICS Administrators, and systems programming personnel. READ access can be given to all authorized users (e.g., auditors, security administrators, and MICS end users). The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have WRITE and/or greater access and, if required, that all WRITE and/or greater access is logged. He will identify if any additional groups have WRITE and/or greater access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system. (Note: The data sets and/or data set prefixes identified below are examples of a possible installation. The actual data sets and/or prefixes are determined when the product is actually installed on a system through the product’s installation guide and can be site specific.) Data sets to be protected will be (additional data sets may be required): SYS2.MICS.DATA. The following commands are provided as a sample for implementing data set controls: ad 'SYS2.MICS.DATA.**' uacc(none) owner(sys2) - audit(failures(read)) - data('Vendor DS Profile: Product') pe 'SYS2.MICS.DATA.**' id(syspaudt tstcaudt micsadm smfbaudt) acc(a) pe 'SYS2.MICS.DATA.**' id(audtaudt micsuser secaaudt) acc(r) setr generic(dataset) refresh