z/OS BMC CONTROL-O for RACF Security Technical Implementation Guide
Pick two releases to diff their requirements.
Open a previous version of this STIG.
Digest of Updates ✎ 5
Comparison against the immediately-prior release (V6R8). Rule matching uses the Group Vuln ID. Content-change detection compares the rule’s description, check, and fix text after stripping inline markup — cosmetic-only edits aren’t flagged.
Content changes 5
- V-224407 Medium fix BMC CONTROL-O configuration/parameter values are not specified properly.
- V-224408 Medium fix BMC CONTROL-O configuration/parameter values are not specified properly.
- V-224409 Medium descriptionfix BMC CONTROL-O security exits are not installed or configured properly.
- V-224410 Medium descriptioncheckfix BMC CONTROL-O installation data sets will be properly protected.
- V-224412 Medium descriptioncheckfix BMC CONTROL-O resources must be properly defined and protected.
- RMF Control
- CM-7
- Severity
- M
- CCI
- CCI-000381
- Version
- ZCTO0040
- Vuln IDs
-
- V-224407
- V-18014
- Rule IDs
-
- SV-224407r1070120_rule
- SV-32004
Checks: C-26084r518836_chk
Refer to the following applicable reports produced by the z/OS Data Collection: - IOA.RPT(SECPARM) Automated Analysis Refer to the following report produced by the z/OS Data Collection: - PDI(ZCTO0040) The following keywords will have the specified values in the BMC CONTROL-O security parameter member: Keyword Value DEFMCHKO $$CTOEDM SECTOLO NO DFMO01 EXTEND DFMO02 EXTEND DFMO03 EXTEND DFMO04 EXTEND DFMO08 EXTEND DFMO10 PROD (new for 6.3.xx) DFMO15 EXTEND
Fix: F-26072r1070119_fix
The BMC CONTROL-O systems programmer will verify that any configuration/parameters that are required to control the security of the product are properly configured and syntactically correct. Set the standard values for the BMC CONTROL-O security parameters for the specific Access Control Program (ACP) environment along with additional IOA security parameters with standard values as documented below. Keyword Value DEFMCHKO $$CTOEDM SECTOLO NO DFMO01 EXTEND DFMO02 EXTEND DFMO03 EXTEND DFMO04 EXTEND DFMO08 EXTEND DFMO10 PROD (new for 6.3.xx) DFMO15 EXTEND
- RMF Control
- CM-7
- Severity
- M
- CCI
- CCI-000381
- Version
- ZCTO0041
- Vuln IDs
-
- V-224408
- V-22689
- Rule IDs
-
- SV-224408r1070118_rule
- SV-32006
Checks: C-26085r518839_chk
Refer to the following applicable reports produced by the z/OS Data Collection: - IOA.RPT(CTOPARM) Automated Analysis Refer to the following report produced by the z/OS Data Collection: - PDI(ZCTO0041) The following keywords will have the specified values in the BMC CONTROL-O security parameter member: Keyword Value RUNTDFT OWNER RUNTCACH 100 AUTOMLOG V
Fix: F-26073r1070117_fix
The BMC CONTROL-O systems programmer will verify that any configuration/parameters that are required to control the security of the product are properly configured and syntactically correct. Set the standard values for the BMC CONTROL-O security parameters for the specific Access Control Program (ACP) environment along with additional IOA security parameters with standard values as documented below. Keyword Value RUNTDFT OWNER RUNTCACH 100 AUTOMLOG V
- RMF Control
- CM-3
- Severity
- M
- CCI
- CCI-001744
- Version
- ZCTO0060
- Vuln IDs
-
- V-224409
- V-17985
- Rule IDs
-
- SV-224409r1070108_rule
- SV-32016
Checks: C-26086r1070106_chk
Interview the systems programmer responsible for the BMC CONTROL-O. Determine if the site has modified the following security exit(s): CTOSE01 CTOSE02 CTOSE03 CTOSE04 CTOSE08 CTOSE10 CTOSE15 Ensure the above security exit(s) has (have) not been modified. If the above security exit(s) has (have) been modified, ensure that the security exit(s) has (have) been approved by the site systems programmer and the approval is on file for examination.
Fix: F-26074r1070107_fix
The system programmer responsible for the BMC CONTROL-O will review the BMC CONTROL-O operating environment. Ensure that the following security exit(s) is (are) installed properly. Determine if the site has modified the following security exit(s): CTOSE01 CTOSE02 CTOSE03 CTOSE04 CTOSE08 CTOSE10 CTOSE15 Ensure that the security exit(s) has (have) not been modified. If the security exit(s) has (have) been modified, ensure the security exit(s) has (have) been checked as to not violate any security integrity within the system and approval documentation is on file.
- RMF Control
- CM-5
- Severity
- M
- CCI
- CCI-001499
- Version
- ZCTOR000
- Vuln IDs
-
- V-224410
- V-16932
- Rule IDs
-
- SV-224410r1070128_rule
- SV-31908
Checks: C-26087r1070126_chk
Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(CTORPT) Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZCTO0000) Verify that the accesses to the BMC CONTROL-O installation data sets are properly restricted. If the following guidance is true, this is not a finding. The RACF data set rules for the data sets restricts READ access to auditors, BMC users, and BMC STCs and/or batch users. The RACF data set rules for the data sets restricts WRITE and/or greater access to systems programming personnel. The RACF data set rules for the data sets specify that all (i.e., failures and successes) WRITE and/or greater access are logged. The RACF data set rules for the data sets specify UACC(NONE) and NOWARNING.
Fix: F-26075r1070127_fix
The ISSO will ensure that WRITE and/or greater access to BMC CONTROL-O installation data sets are limited to systems programmers only, and all WRITE and/or greater access is logged. READ access can be given to auditors, BMC users, and BMC STCs and/or batch users. All failures and successful WRITE and/or greater accesses are logged. The installing systems programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. The installing systems programmer will identify if any additional groups have update and/or alter access for specific data sets, and once documented, will work with the ISSO to ensure they are properly restricted to the Access Control Program (ACP) active on the system. (Note: The data sets and/or data set prefixes identified below are examples of a possible installation. The actual data sets and/or prefixes are determined when the product is actually installed on a system through the product's installation guide and can be site specific.) Data sets to be protected will be: SYS2.IOA.*.CTOI. The following commands are provided as a sample for implementing data set controls: ad 'SYS2.IOA.*.CTOI.**' uacc(none) owner(sys2) - audit(success(update) failures(read)) - data('Vendor DS Profile: BMC CONTROL-O') pe 'SYS2.IOA.*.CTOI.**' id(<syspaudt>) acc(a) pe 'SYS2.IOA.*.CTOI.**' id(<audtaudt> <bmcuser>) acc(r) pe 'SYS2.IOA.*.CTOI.**' id(CONTROLO) acc(r) setr generic(dataset) refresh
- RMF Control
- CM-5
- Severity
- M
- CCI
- CCI-001499
- Version
- ZCTOR001
- Vuln IDs
-
- V-224411
- V-17067
- Rule IDs
-
- SV-224411r958616_rule
- SV-31944
Checks: C-26088r518848_chk
Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(CTOSTC) Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZCTO0001) Verify that the accesses to the BMC CONTROL-O STC data sets are properly restricted. If the following guidance is true, this is not a finding. ___ The RACF data set access authorizations restrict READ access to auditors, operators, and domain level production control and scheduling personnel. ___ The RACF data set access authorizations restrict WRITE and/or greater access to systems programming personnel. ___ The RACF data set access authorizations restrict UPDATE access to the BMC users and BMC STCs and/or batch users. ___ The RACF data set access authorizations specify UACC(NONE) and NOWARNING.
Fix: F-26076r518849_fix
The ISSO will ensure that WRITE and/or greater access to BMC CONTROL-O STC data sets are limited to System Programmers only. UPDATE access can be given to BMC users and the BMC STCs and/or batch users. READ access can be given to auditors, operators, and domain level production control and scheduling personnel. The installing systems programmer will identify and document the product data sets and categorize them according to who will have what type of access and if required which type of access is logged. The installing systems programmer will identify any additional groups requiring access to specific data sets, and once documented the installing systems programmer will work with the ISSO to see that they are properly restricted to the ACP (Access Control Program) active on the system. Data sets to be protected will be: SYS3.IOA.*.CTOO.** The following commands are provided as a sample for implementing data set controls: ad 'SYS3.IOA.*.CTOO.**' uacc(none) owner(sys3) - audit(failures(read)) - data('BMC CONTROL-O Operational & Repository') pe 'SYS3.IOA.*.CTOO.**' id(<syspaudt>) acc(a) pe 'SYS3.IOA.*.CTOO.**' id(CONTROLO) acc(u) pe 'SYS3.IOA.*.CTOO.**' id(<bmcuser> <bmcbatch>) acc(u) pe 'SYS3.IOA.*.CTOO.**' id(<audtaudt>) acc(r) pe 'SYS3.IOA.*.CTOO.**' id(<operaudt>) acc(r) pe 'SYS3.IOA.*.CTOO.**' id(<pcspaudt>) acc(r) setr generic(dataset) refresh
- RMF Control
- AC-3
- Severity
- M
- CCI
- CCI-000213
- Version
- ZCTOR020
- Vuln IDs
-
- V-224412
- V-17947
- Rule IDs
-
- SV-224412r1070161_rule
- SV-32062
Checks: C-26089r1070159_chk
Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(ZCTO0020) Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZCTO0020) Verify that the accesses to resources and/or generic equivalent are properly restricted according to the requirements specified in BMC CONTROL-O Resources table in the z/OS STIG Addendum. If the following guidance is true, this is not a finding. Note: To determine what resource class is used review the IOACLASS setting in SECPARM. The "Trigger" resources i.e., $$SECxxx (xxx is unique to the product) are defined in the FACILITY resource class The RACF resources are defined with a default access of NONE. The RACF resource access authorizations restrict access to the appropriate personnel. The RACF resource logging requirements are specified. The RACF resource access authorizations are defined with UACC(NONE) and NOWARNING.
Fix: F-26077r1070160_fix
The ISSO will work with the systems programmer to verify that the following are properly specified in the Access Control Program (ACP). Note: To determine what resource class is used review the IOACLASS setting in SECPARM. The "Trigger" resources i.e., $$SECxxx (xxx is unique to the product) are defined in the FACILITY resource class (Note: The resource class, resources, and/or resource prefixes identified below are examples of a possible installation. The actual resource class, resources, and/or resource prefixes are determined when the product is actually installed on a system through the product's installation guide and can be site specific.) Use BMC CONTROL-O Resources and BMC INCONTROL Resources Descriptions tables in the z/OS STIG Addendum. These tables list the resources, descriptions, and access and logging requirements. Ensure the guidelines for the resources and/or generic equivalent specified in the z/OS STIG Addendum are followed. The following commands are provided as a sample for implementing resource controls: $key($$ctoaop) type(ioa) - uid(<operaudt>) log - uid(<pcspaudt>) log - uid(<prodaudt>) log - uid(<syspaudt>) log - uid(*) prevent
- RMF Control
- IA-2
- Severity
- M
- CCI
- CCI-000764
- Version
- ZCTOR030
- Vuln IDs
-
- V-224413
- V-17452
- Rule IDs
-
- SV-224413r958482_rule
- SV-32074
Checks: C-26090r518854_chk
Refer to the following report produced by the RACF Data Collection: - RACFCMDS.RPT(LISTUSER) The BMC CONTROL-O started task(s) and/or batch job userid(s) is defined and is assigned the RACF PROTECTED attribute.
Fix: F-26078r518855_fix
The BMC CONTROL-O system programmer and the IAO will ensure that a product's Started Task(s) is properly Identified / defined to the System ACP. If the product requires a Started Task, verify that it is properly defined to the System ACP with the proper attributes. Most installation manuals will indicate how the Started Task is identified and any additional attributes that must be specified. A sample is provided here: au CONTROLO name('stc, BMC CONTROL-O') owner(stc) dfltgrp(stc) nopass
- RMF Control
- IA-2
- Severity
- M
- CCI
- CCI-000764
- Version
- ZCTOR032
- Vuln IDs
-
- V-224414
- V-17454
- Rule IDs
-
- SV-224414r958482_rule
- SV-32175
Checks: C-26091r518857_chk
Refer to the following report produced by the RACF Data Collection: - DSMON.RPT(RACSPT) Automated Analysis Refer to the following report produced by the RACF Data Collection: - PDI(ZCTO0032) Verify that the BMC CONTROL-O started task(s) is (are) defined to the STARTED resource class profile and/or ICHRIN03 table entry.
Fix: F-26079r518858_fix
The BMC CONTROL-O system programmer and the IAO will ensure that a product's started task(s) is (are) properly identified and/or defined to the System ACP. A unique userid must be assigned for the BMC CONTROL-O started task(s) thru a corresponding STARTED class entry. The following sample set of commands is shown here as a guideline: rdef started CONTROLO.** uacc(none) owner(admin) audit(all(read)) stdata(user(CONTROLO) group(stc)) setr racl(started) ref