z/OS BMC CONTROL-M/Restart for RACF STIG
Pick two releases to diff their requirements.
Open a previous version of this STIG.
- RMF Control
- Severity
- M
- CCI
- Version
- ZCTRR000
- Vuln IDs
-
- V-16932
- Rule IDs
-
- SV-31832r2_rule
Checks: C-6186r2_chk
Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(CTRRPT) Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZCTR0000) Verify that the accesses to the BMC CONTROL-M/Restart installation data sets are properly restricted. If the following guidance is true, this is not a finding. ___ The RACF data set access authorizations restrict READ access to auditors, BMC users, and BMC STCs and/or batch users. ___ The RACF data set access authorizations restrict WRITE and/or greater access to systems programming personnel. ___ The RACF data set access authorizations specify that all (i.e., failures and successes) WRITE and/or greater access are logged. ___ The RACF data set access authorizations specify UACC(NONE) and NOWARNING.
Fix: F-3268r5_fix
The IAO will ensure that WRITE and/or greater access to BMC CONTROL-M/Restart installation data sets are limited to System Programmers only, and all WRITE and/or greater access is logged. READ access can be given to auditors, BMC users, and BMC STCs and/or batch users. All failures and successful WRITE and/or greater accesses are logged. The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. He will identify if any additional groups have update and/or alter access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system. (Note: The data sets and/or data set prefixes identified below are examples of a possible installation. The actual data sets and/or prefixes are determined when the product is actually installed on a system through the product’s installation guide and can be site specific.) Data sets to be protected will be: SYS2.IOA.*.CTRO. The following commands are provided as a sample for implementing data set controls: ad 'SYS2.IOA.*.CTRO.**' uacc(none) owner(sys2) - audit(success(update) failures(read)) - data('Vendor DS Profile: BMC CONTROL-M/Restart') pe 'SYS2.IOA.*.CTRO.**' id(<syspaudt>) acc(a) pe 'SYS2.IOA.*.CTRO.**' id(<audtaudt> <bmcuser>) acc(r) pe 'SYS2.IOA.*.CTRO.**' id(CONTROLR) acc(r) setr generic(dataset) refresh
- RMF Control
- Severity
- M
- CCI
- Version
- ZCTRR002
- Vuln IDs
-
- V-21592
- Rule IDs
-
- SV-32219r2_rule
Checks: C-3334r3_chk
Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(CTRUSER) Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZCTR0002) Verify that the accesses to the BMC CONTROL-M/Restart Archived Sysout data sets are properly restricted. If the following guidance is true, this is not a finding. ___ The RACF data set access authorizations restrict READ access to auditors, Production Control Scheduling personnel, and scheduled batch user(s). ___ The RACF data set access authorizations restrict WRITE and/or greater access to systems programming personnel and the BMC STCs and/or batch users. ___ The RACF data set access authorizations specify UACC(NONE) and NOWARNING.
Fix: F-3243r4_fix
The IAO will ensure that WRITE and/or greater access to BMC CONTROL-M/Restart Archived Sysout data sets are limited to System Programmers and the BMC STCs and/or batch users only. READ access can be given to auditors, production control scheduling personnel, and scheduled batch users. The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. He will identify if any additional groups have update and/or alter access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system. (Note: The data sets and/or data set prefixes identified below are examples of a possible installation. The actual data sets and/or prefixes are determined when the product is actually installed on a system through the product’s installation guide and can be site specific.) Data sets to be protected will be: CTRSYS. The following commands are provided as a sample for implementing data set controls: ad 'CTRSYS.**' uacc(none) owner(CTRSYS) - data('BMC CONTROL-M/Restart Archived Sysout') pe 'CTRSYS.**' id(CONTROLM CONTDAY) acc(a) pe 'CTRSYS.**' id(<syspaudt>) acc(a) pe 'CTRSYS.**' id(<audtaudt> <autoaudt> <pcspaudt>) acc(r) setr generic(dataset) refresh