z/OS BMC CONTROL-M/Restart for ACF2 Security Technical Implementation Guide
Pick two releases to diff their requirements.
Open a previous version of this STIG.
Digest of Updates ✎ 2
Comparison against the immediately-prior release (V6R6). Rule matching uses the Group Vuln ID. Content-change detection compares the rule’s description, check, and fix text after stripping inline markup — cosmetic-only edits aren’t flagged.
Content changes 2
- RMF Control
- CM-5
- Severity
- M
- CCI
- CCI-001499
- Version
- ZCTRA000
- Vuln IDs
-
- V-224121
- V-16932
- Rule IDs
-
- SV-224121r1070020_rule
- SV-31831
Checks: C-25794r1070018_chk
Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(CTRRPT) Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZCTR0000) Verify that the accesses to the BMC CONTROL-M/Restart installation data sets are properly restricted. If the following guidance is true, this is not a finding. The ACF2 data set access authorizations restrict READ access to auditors, BMC users, and BMC STCs and/or batch users. The ACF2 data set access authorizations restrict WRITE and/or greater access to systems programming personnel. The ACF2 data set access authorizations specify that all (i.e., failures and successes) WRITE and/or greater access are logged.
Fix: F-25782r1070019_fix
The ISSO will ensure that WRITE and/or greater access to BMC CONTROL-M/Restart installation data sets are limited to systems programmers only, and all WRITE and/or greater access is logged. READ access can be given to auditors, BMC users, and BMC STCs and/or batch users. All failures and successful WRITE and/or greater accesses are logged. The installing systems programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. The installing systems programmer will identify if any additional groups have update and/or alter access for specific data sets, and once documented, will work with the ISSO to ensure they are properly restricted to the Access Control Program (ACP) active on the system. (Note: The data sets and/or data set prefixes identified below are examples of a possible installation. The actual data sets and/or prefixes are determined when the product is actually installed on a system through the product's installation guide and can be site specific.) Data sets to be protected will be: SYS2.IOA.*.CTRO. The following commands are provided as a sample for implementing data set controls: $KEY(SYS2) IOA.-.CTRO.- UID(<syspaudt>) R(A) W(L) A(L) E(A) IOA.-.CTRO.- UID(<audtaudt>) R(A) E(A) IOA.-.CTRO.- UID(<bmcuser>) R(A) E(A) IOA.-.CTRO.- UID(CONTROLR) R(A) E(A)
- RMF Control
- CM-5
- Severity
- M
- CCI
- CCI-001499
- Version
- ZCTRA002
- Vuln IDs
-
- V-224122
- V-21592
- Rule IDs
-
- SV-224122r1070023_rule
- SV-32218
Checks: C-25795r1070021_chk
Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(CTRUSER) Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZCTR0002) Verify that the accesses to the BMC CONTROL-M/Restart Archived Sysout data sets are properly restricted. If the following guidance is true, this is not a finding. The ACF2 data set access authorizations restrict READ access to auditors and BMC Users. The ACF2 data set access authorizations restrict WRITE and/or greater access to Production Control Scheduling personnel, scheduled batch user(s), systems programming personnel, and the BMC STCs and/or batch users.
Fix: F-25783r1070022_fix
Ensure that WRITE and/or greater access to BMC CONTROL-M/Restart Archived Sysout data sets are limited to production control scheduling personnel, scheduled batch users, systems programmers, and the BMC STCs and/or batch users only. READ access can be given to auditors and BMC users. The installing systems programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. The installing systems programmer will identify if any additional groups have update and/or alter access for specific data sets, and once documented, will work with the ISSO to ensure they are properly restricted to the Access Control Program (ACP) active on the system. (Note: The data sets and/or data set prefixes identified below are examples of a possible installation. The actual data sets and/or prefixes are determined when the product is actually installed on a system through the product's installation guide and can be site specific.) Data sets to be protected will be: CTRSYS. The following commands are provided as a sample for implementing data set controls: $KEY(CTRSYS) - UID(<syspaudt>) R(A) W(A) A(A) E(A) - UID(CONTROLM) R(A) W(A) A(A) E(A) - UID(CONTDAY) R(A) W(A) A(A) E(A) - UID(<audtaudt>) R(A) E(A) - UID(<bmcuser>) R(A) E(A) - UID(<autoaudt>) R(A) W(A) A(A) E(A) - UID(<pcspaudt>) R(A) W(A) A(A) E(A)