Reviewer with the assistance of the IAO/NSO, verify that the default zone visibility setting is set to “none”.. If this setting is not available mark this check as N/A.
Locate all clients that have not been explicitly placed into a zone. Create a plan to explicitly place these clients into the correct zone(s) and after doing so the plan will include the modification of the default zone visibility setting to “none”. Obtain CM approval of the plan and then, following the plan, reconfigure the SAN to allow for the default zone visibility setting to be set to “none”.
The reviewer, with the assistance of the IAO/NSO, will verify that hard zoning is used to protect the SAN. If soft zoning is used, this is a finding. If soft zoning must be used (with DAA approval), this is still a CAT II finding and a migration plan must be in place. However, note that the HBA’s memory is non-persistent, thus when zoning changes are made, a policy must be in place (show via the log that it is enforced) to force a state change update in the affected HBAs immediately after making zoning changes.
If zoning has not been implemented, develop a zone topography. From the topography, create a plan to implement hard zoning, obtain CM approval of the plan and then, following the plan, reconfigure the SAN to support hard zoning. If zoning has been implemented, develop a plan to migrate to hard zoning, obtain CM approval of the plan and then, following the plan, reconfigure the SAN to support hard zoning.
The reviewer will interview the IAO/NSO to validate that SANs are compliant with overall network security architecture, appropriate enclave, and data center security requirements in the Network Infrastructure STIG and the Enclave STIG. NOTE: The intent of this check is to ensure that the other checklists were applied. If they are applied then, regardless of what the findings are, this is not a finding. The objective of this policy is met if the other checklists were applied and documented.
Perform a self assessment with the Network Infrastructure checklist and the Enclave checklist or schedule a formal review with FSO.
The reviewer will, with the assistance of the IAO/NSO, verify that all security related patches are installed.
After verifying that the patches do not adversely impact the production SAN, create a plan for installing the patches on the SAN, obtain CM approval of the plan, and implement the plan installing the patches.
The reviewer will interview the IAO/NSO and view VMS to verify that prior to installing SAN components (servers, switches, and management stations) onto the DOD network infrastructure, components are configured to meet the applicable STIG requirements.
Perform a self assessment using the applicable checklists or scripts on any component device that has not been reviewed or request a formal review from FSO.
The reviewer will interview the IAO/NSO and view the VMS to verify that servers and other hosts are compliant with applicable Operating System (OS) STIG requirements.
Perform a self assessment using the applicable OS checklists or scripts on any server or host in the SAN that has not been reviewer or request a formal review from FSO.
The reviewer will verify that vendor supported, DOD approved, anti-virus software is installed and configured on all SAN servers in accordance with the applicable operating system STIG on SAN servers and management devices and kept up-to-date with the most recent virus definition tables. If an OS review has reciently been completed verify that the anti-virus check was not a finding. Otherwise perform a manual check as described in the applicable OS checklist.
Install and correctly configure a DOD approved anti-virus.
The reviewer will interview the IAO/NSO and view the drawings supplied to verify that a current drawing of the site’s SAN topology that includes all external and internal links, zones, and all interconnected equipment.
Create drawing of the site’s SAN topology that includes all external and internal links, zones, and all interconnected equipment.
The reviewer will interview the IAO/NSO and view the network level devices to verify whether they are located in a secure room with limited access.
Develop a plan to move the network level devices to a location/room where the can be physically secured in a manner appropriate to the classification level of the data the handle. Obtain CM approval of the plan and then implement the plan moving the devices.
The reviewer, with the assistance of the IAO/NSO, will verify that individual user accounts with passwords are set up and maintained for the SAN fabric switch.
Develop a plan to reconfigure the SAN fabric switch to require user accounts and passwords. This plan also needs to include the creation and distribution of user accounts and passwords for each administrator who requires access to the SAN fabric switch. Obtain CM approval of the plan and then implement the plan.
Verify that all fabric switches are configured to bidirectional authentication.
Configure the SAN fabric switches to use bidirectional authentication between switches.
The reviewer will, with the assistance of the IAO/NSO, verify fabric switches are protected by DOD PKI. View the installed device certificates. Verify a DoD -approved certificate is loaded. If any of the certificates have the name or identifier of a non-DoD- approved source in the Issuer field, this is a finding.
Generate a new key-pair from a DoD-approved certificate issuer. Sites must consult the PKI/PKI pages on the http://iase.disa.mil/ website for procedures for NIPRNet and SIPRNet.
The reviewer will, with the assistance of the IAO/NSO, verify that all network management ports on the SAN fabric switches are disabled except those needed to support the operational commitments of the sites.
Develop a plan to locate and disable all network management ports that are not required to support the operational commitments of the sites. Obtain CM approval of the plan and then execute the plan.
The reviewer will interview the IAO and view the SAN network drawings provided.
Develop a plan to migrate the SAN management to an out-of-band network or a direct connect method. Obtain CM approval for the plan and implement the plan.
The reviewer will, with the assistance of the IAO/NSO, verify that communications from the management console to the SAN fabric are protected using DOD PKI. If another method of two-factor authentication is used, then inspect approval documentation. If two-factor authentication is not used, this is a finding. If two-factor authentication method is not DoD PKI and no approval documentation exists, this is a finding.
Develop a plan to migrate to the use of DoD PKI authentication between the SAN management console and the SAN fabric. Obtain CM approval of the plan and implement the plan.
The reviewer will, with the assistance of the IAO/NSO, verify that the manufacturer’s default PKI keys have been changed prior to attaching the switch to the SAN Fabric.
Depending on the functionality allowed by the device, develop a plan remove, disable or change the manufacturer’s default PKI certificate so that it cannot be used for identification and authorization. Obtain CM approval for the plan and implement the plan.
The reviewer will, with the assistance of the storage administrator, verify that the SAN is configured to use FIPS 140-1/2 validated encryption algorithm to protect management-to-fabric communications.
Develop a plan to implement FIPS-140-1/2 validated encryption to protect management-to-fabric communications. Obtain CM approval of the plan and execute the plan.
The reviewer will, with the assistance of the IAO/NSO, verify that all SAN management consoles and ports are password protected.
Develop a plan for implementing password protection on the SAN’s management consoles and ports. Obtain CM approval of the plan and execute the plan.
The reviewer will, with the assistance of the IAO/NSO, verify that the manufacturer’s default passwords have been changed for all SAN management software.
Develop a plan to change manufacturer’s default passwords for all SAN management software. Obtain CM approval of the plan and implement the plan.
The reviewer will, with the assistance of the IAO/NSO, verify that SAN fabric zoning lists are based on a policy of Deny-by-Default with blocks on all services and protocols not required on the given port or by the site.
Develop a plan to identify all services and protocols needed by each port in the SAN, modify the routing lists to enforce a Deny-by-Default policy and allow only the identified services and protocols on each port that requires them. Obtain CM approval for the plan and implement the plan.
The reviewer will, with the assistance of the IAO/NSO, verify that all attempts to any port, protocol, or service that is denied are logged.
Develop a plan to implement the logging of failed or rejected ports, protocols or services requests. The plan should include a projection of the storage requirements of the logged events. Obtain CM approval of the plan and execute it.
With the assistance of the IAO/NSO, verify that if Simple Network Management Protocol (SNMP) is used, it is configured in accordance with the guidance contained in the Network Infrastructure STIG. NOTE: The intent of this check is to ensure that the other checklists were applied. If they are applied then, regardless of what the findings are, this is not a finding. The objective of this policy is met if the other checklist was applied and documented.
Develop a plan to implement SNMP that is compliant with the Network Infrastructure STIG. Obtain CM approval and execute the plan. NOTE: The intent of this check is to ensure that the other applicable checklists were applied. If they are applied then, regardless of what the findings are, this is not a finding. The objective of this policy is met if the other checklists were applied and documented.
The reviewer will, with the assistance of the IAO/NSO, verify that only authorized IP addresses are allowed Simple Network Management Protocol (SNMP) access to the SAN devices. This can be done with by checking the ACLs for the SAN device ports.
Develop a plan to restrict SNMP access to SAN devices to authorized IP addresses. Obtain CM approval for the plan and implement the plan.
The reviewer will, with the assistance of the IAO/NSO, verify that the IP addresses of the hosts permitted SNMP access to the SAN management devices belong to the internal network. The ACLs for the SAN ports should be checked.
Develop a plan to restrict SNMP access to SAN devices to only internal network IP addresses. Obtain CM approval of the plan and implement the plan.
The reviewer will, with the assistance of the IAO/NSO, verify that end-user platforms are not directly attached to the Fibre Channel network and may not access storage devices directly. If the SAN is small with all of its components collocated, this can be done by a visual inspection but in most cases the reviewer will have to check the SAN network drawing.
Develop a plan to remove end-user platforms from the SAN. Obtain CM approval for the plan and implement the plan.
The reviewer will interview the IAO/NSO and view the stored information to verify that all fabric switch configurations and management station configuration are archived and copies of the operating system and other critical software for all SAN components are stored in a fire rated container or otherwise not collocated with the operational software.
Develop a plan that will ensure that all fabric switch configurations and management station configuration are archived and copies of the operating system and other critical software for all SAN components are stored in a fire rated container or otherwise not collocated with the operational software. Obtain CM approval for the plan and implement the plan.
The reviewer with the assistance of the SA will verify that all SAN components are configured with fixed IP addresses.
Configure all SAN components to have fixed IP addresses.