This Security Technical Implementation Guide is published as a tool to improve the security of Department of Defense (DoD) information systems. The requirements are derived from the National Institute of Standards and Technology (NIST) 800-53 and related documents. Comments or proposed revisions to this document should be sent via email to the following address: disa.stig_spt@mail.mil.
b
BMC MAINVIEW for z/OS installation data sets are not properly protected.
AC-3 - Medium - CCI-000213 - V-224607 - SV-224607r855099_rule
RMF Control
AC-3
Severity
Medium
CCI
CCI-000213
Version
ZMVZT000
Vuln IDs
  • V-224607
  • V-16932
Rule IDs
  • SV-224607r855099_rule
  • SV-33837
BMC MAINVIEW for z/OS installation data sets have the ability to use privileged functions and/or have access to sensitive data. Failure to properly restrict access to these data sets could result in violating the integrity of the base product which could result in compromising the operating system or sensitive data.
Checks: C-26290r518998_chk

Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(MVZRPT) Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZMVZ0000) Verify that the accesses to the BMC MAINVIEW for z/OS installation data sets are properly restricted. ___ The TSS data set rules for the data sets restricts READ access to all authorized users. ___ The TSS data set rules for the data sets restricts UPDATE and/or ALL access to systems programming personnel. ___ The TSS data set rules for the data sets specify that all (i.e., failures and successes) UPDATE and/or ALL access are logged.

Fix: F-26278r518999_fix

The IAO will ensure that update and allocate access to BMC MAINVIEW for z/OS installation data sets is limited to System Programmers only, and all update and allocate access is logged. Read access can be given to all authorized users. The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. He will identify if any additional groups have update and/or alter access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system. Data sets to be protected will be: SYS2.BMCVIEW. SYS3.BMCVIEW. (data sets that are not altered by product STCs, can be more specific) The following commands are provided as a sample for implementing data set controls: TSS PERMIT(<syspaudt>) DSN(SYS2.BMCVIEW.) ACCESS(R) TSS PERMIT(<syspaudt>) DSN(SYS2.BMCVIEW.) ACCESS(ALL) ACTION(AUDIT) TSS PERMIT(<tstcaudt>) DSN(SYS2.BMCVIEW.) ACCESS(R) TSS PERMIT(<tstcaudt>) DSN(SYS2.BMCVIEW.) ACCESS(ALL) ACTION(AUDIT) TSS PERMIT(<audtaudt>) DSN(SYS2.BMCVIEW.) ACCESS(R) TSS PERMIT(authorized users) DSN(SYS2.BMCVIEW.) ACCESS(R) TSS PERMIT(MAINVIEW STCs) DSN(SYS2.BMCVIEW.) ACCESS(R) TSS PERMIT(<syspaudt>) DSN(SYS3.BMCVIEW.) ACCESS(R) TSS PERMIT(<syspaudt>) DSN(SYS3.BMCVIEW.) ACCESS(ALL) ACTION(AUDIT) TSS PERMIT(<tstcaudt>) DSN(SYS3.BMCVIEW.) ACCESS(R) TSS PERMIT(<tstcaudt>) DSN(SYS3.BMCVIEW.) ACCESS(ALL) ACTION(AUDIT) TSS PERMIT(<audtaudt>) DSN(SYS3.BMCVIEW.) ACCESS(R) TSS PERMIT(authorized users) DSN(SYS3.BMCVIEW.) ACCESS(R) TSS PERMIT(MAINVIEW STCs) DSN(SYS3.BMCVIEW.) ACCESS(R)

b
BMC MAINVIEW for z/OS STC data sets are not properly protected.
CM-5 - Medium - CCI-001499 - V-224608 - SV-224608r868735_rule
RMF Control
CM-5
Severity
Medium
CCI
CCI-001499
Version
ZMVZT001
Vuln IDs
  • V-224608
  • V-17067
Rule IDs
  • SV-224608r868735_rule
  • SV-37724
BMC MAINVIEW for z/OS STC data sets have the ability to use privileged functions and/or have access to sensitive data. Failure to properly restrict access to these data sets could result in violating the integrity of the base product which could result in compromising the operating system or sensitive data.
Checks: C-26291r868733_chk

Refer to the following report produced by the Data Set and Resource Data Collection: - SENSITVE.RPT(MVZSTC) Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZMVZ0001) Verify that the accesses to the BMC MAINVIEW for z/OS STC data sets are properly restricted. ___ The TSS data set rules for the data sets restricts READ access to auditors and authorized users. ___ The TSS data set rules for the data sets restricts UPDATE and/or ALL access to systems programming personnel. ___ The TSS data set rules for the data sets restricts UPDATE and/or ALL access to the BMC MAINVIEW for z/OS's STC(s) and/or batch user(s).

Fix: F-26279r868734_fix

The ISSO will ensure that update and allocate access to BMC MAINVIEW for z/OS STC data sets is limited to systems programmers and/or BMC MAINVIEW for z/OS's STC(s) and/or batch user(s) only. Read access can be given to auditors and authorized users. The installing systems programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. The installing systems programmer will identify if any additional groups have update and/or alter access for specific data sets, and once documented will work with the ISSO to ensure they are properly restricted to the ACP (Access Control Program) active on the system. Data sets to be protected will be: SYS3.BMCVIEW (data sets that are altered by the product's STCs, this can be more specific) The following commands are provided as a sample for implementing data set controls: TSS PERMIT(<syspaudt>) DSN(SYS3.BMCVIEW) ACCESS(ALL) TSS PERMIT(<tstcaudt>) DSN(SYS3.BMCVIEW) ACCESS(ALL) TSS PERMIT(MAINVIEW STCs) DSN(SYS3.BMCVIEW) ACCESS(ALL) TSS PERMIT(<audtaudt>) DSN(SYS3.BMCVIEW) ACCESS(R) TSS PERMIT(authorize user) DSN(SYS3.BMCVIEW) ACCESS(R)

b
BMC MAINVIEW resources must be properly defined and protected.
AC-4 - Medium - CCI-000035 - V-224609 - SV-224609r868738_rule
RMF Control
AC-4
Severity
Medium
CCI
CCI-000035
Version
ZMVZT020
Vuln IDs
  • V-224609
  • V-17947
Rule IDs
  • SV-224609r868738_rule
  • SV-46313
BMC MAINVIEW can run with sensitive system privileges, and potentially can circumvent system controls. Failure to properly control access to product resources could result in the compromise of the operating system environment, and compromise the confidentiality of customer data. Many utilities assign resource controls that can be granted to systems programmers only in greater than read authority. Resources are also granted to certain non systems personnel with read only authority.
Checks: C-26292r868736_chk

Refer to the following report produced by the TSS Data Collection and Data Set and Resource Data Collection: - SENSITVE.RPT(ZMVZ0020) - TSSCMDS.RPT(#RDT) Automated Analysis Refer to the following report produced by the Data Set and Resource Data Collection: - PDI(ZMVZ0020) Verify that the accesses to resources and/or generic equivalent are properly restricted according to the requirements specified in BMC MAINVIEW Resources table in the z/OS STIG Addendum. If the following guidance is true, this is not a finding. ___ The TSS resources are owned or DEFPROT is specified for the resource class. ___ The TSS resource access authorizations restrict access to the appropriate personnel.

Fix: F-26280r868737_fix

The ISSO will work with the systems programmer to verify that the following are properly specified in the ACP. (Note: The resource class, resources, and/or resource prefixes identified below are examples of a possible installation. The resource class, actual resources, and/or prefixes are determined when the product is actually installed on a system through the product's installation guide and can be site specific.) Use BMC MAINVIEW Resources table in the zOS STIG Addendum. This table lists the resources, access requirements, and logging requirement for BMC MAINVIEW. Ensure the guidelines for the resources and/or generic equivalent specified in the z/OS STIG Addendum are followed. The TSS resources as designated in the above table are owned and/or DEFPROT is specified for the resource class. The TSS resource access authorizations restrict access to the appropriate personnel as designated in the above table. The following commands are provided as a sample for implementing resource controls: TSS ADD(dept-acid) #BMCVIEW(BBM) TSS PERMIT(autoaudt) #BMCVIEW(BBM.ssid.CN) ACCESS(ALL) TSS PERMIT(dasdaudt) #BMCVIEW(BBM.ssid.CN) ACCESS(ALL) TSS PERMIT(mqsaaudt) #BMCVIEW(BBM.ssid.CN) ACCESS(ALL) TSS PERMIT(Mainview STCs) #BMCVIEW(BBM.ssid.CN) ACCESS(ALL) TSS PERMIT(mvzread) #BMCVIEW(BBM.ssid.CN) ACCESS(ALL) TSS PERMIT(mvzupdt) #BMCVIEW(BBM.ssid.CN) ACCESS(ALL) TSS PERMIT(pcspaudt) #BMCVIEW(BBM.ssid.CN) ACCESS(ALL) TSS PERMIT(syspaudt) #BMCVIEW(BBM.ssid.CN) ACCESS(ALL)

b
BMC Mainview for z/OS Started Task name is not properly identified and/or defined to the system ACP.
IA-2 - Medium - CCI-000764 - V-224610 - SV-224610r519009_rule
RMF Control
IA-2
Severity
Medium
CCI
CCI-000764
Version
ZMVZT030
Vuln IDs
  • V-224610
  • V-17452
Rule IDs
  • SV-224610r519009_rule
  • SV-33840
BMC Mainview for z/OS requires a started task that will be restricted to certain resources, datasets and other system functions. By defining the started task as a userid to the system ACP, It allows the ACP to control the access and authorized users that require these capabilities. Failure to properly control these capabilities, could compromise of the operating system environment, ACP, and customer data.
Checks: C-26293r519007_chk

Refer to the following report produced by the TSS Data Collection: - TSSCMDS.RPT(@ACIDS) Review each BMC Mainview for z/OS STC/Batch ACID(s) for the following: ___ Defined with Facility of STC, BBI3 (the TSS FACILITY Matrix Table entry defined for this product), and/or BATCH for MV$CAS, MV$PAS, and MV$MVS. ___ Defined with Master Facility of BBI3 (the TSS FACILITY Matrix Table entry defined for this product) for MV$CAS and MV$PAS. ___ Is sourced to the INTRDR.

Fix: F-26281r519008_fix

The BMC Mainview for z/OS system programmer and the IAO will ensure that a product's Started Task(s) is properly identified and/or defined to the System ACP. If the product requires a Started Task, verify that it is properly defined to the System ACP with the proper attributes. Most installation manuals will indicate how the Started Task is identified and any additional attributes that must be specified. A sample is provided here: TSS CREATE(MV$CAS) TYPE(USER) - NAME('CAS, BMC Mainview for z/OS') DEPT(xxxx) - FAC(STC,BBI3) - MASTFAC(BBI3) PASS(xxxxxxxx,0) - SOURCE(INTRDR) NOSUSPEND TSS CREATE(MV$PAS) TYPE(USER) - NAME('PAS, BMC Mainview for z/OS') DEPT(xxxx) - FAC(STC,BBI3) - MASTFAC(BBI3) PASS(xxxxxxxx,0) - SOURCE(INTRDR) NOSUSPEND TSS CREATE(MV$MVS) TYPE(USER) - NAME('MVS, BMC Mainview for z/OS') DEPT(xxxx) - FAC(STC,BBI3) - PASS(xxxxxxxx,0) - SOURCE(INTRDR) NOSUSPEND

b
BMC Mainview for z/OS Started task(s) must be properly defined to the Started Task Table ACID for Top Secret.
IA-2 - Medium - CCI-000764 - V-224611 - SV-224611r519012_rule
RMF Control
IA-2
Severity
Medium
CCI
CCI-000764
Version
ZMVZT032
Vuln IDs
  • V-224611
  • V-17454
Rule IDs
  • SV-224611r519012_rule
  • SV-33842
Access to product resources should be restricted to only those individuals responsible for the application connectivity and who have a requirement to access these resources. Improper control of product resources could potentially compromise the operating system, ACP, and customer data.
Checks: C-26294r519010_chk

Refer to the following report produced by the TSS Data Collection: - TSSCMDS.RPT(#STC) Automated Analysis Refer to the following report produced by the TSS Data Collection: - PDI(ZMVZ0032) Verify that the BMC Mainview for z/OS started task(s) is (are) defined in the TSS STC record.

Fix: F-26282r519011_fix

The BMC Mainview for z/OS system programmer and the IAO will ensure that a product's started task(s) is (are) properly identified and/or defined to the System ACP. A unique ACID must be assigned for the BMC Mainview for z/OS started task(s) thru a corresponding STC table entry. The following sample set of commands is shown here as a guideline: TSS ADD(STC) PROCNAME(MV$CAS) ACID(MV$CAS) TSS ADD(STC) PROCNAME(MV$MVS) ACID(MV$MVS)

b
BMC Mainview for z/OS is not properly defined to the Facility Matrix Table for Top Secret.
IA-2 - Medium - CCI-000764 - V-224612 - SV-224612r519015_rule
RMF Control
IA-2
Severity
Medium
CCI
CCI-000764
Version
ZMVZT036
Vuln IDs
  • V-224612
  • V-17469
Rule IDs
  • SV-224612r519015_rule
  • SV-33843
Improperly defined security controls for BMC Mainview for z/OS could result in the compromise of the network, operating system, and customer data.
Checks: C-26295r519013_chk

Refer to the following report produced by the TSS Data Collection: - TSSCMDS.RPT(FACLIST) - Preferred report containing all control option values in effect including default values - TSSCMDS.RPT(TSSPRMFL) - Alternate report containing only control option values explicitly coded at TSS startup Ensure the BMC Mainview for z/OS Facility Matrix table is defined as follows: BBI3: FAC(USERxx=NAME=BBI3,PGM=BBM,ID=nn,ACTIVE,SHRPRF,ASUBM) FAC(BBI3=NOABEND,MULTIUSER,NOXDEF,SIGN(S),RES,LUMSG) FAC(BBI3=STMSG,WARNPW,NORNDPW,NOAUDIT,NOTSOC,MODE=FAIL) FAC(BBI3=LOG(SMF,INIT,MSG,SEC9),UIDACID=8,LOCKTIME=000)

Fix: F-26283r519014_fix

The BMC Mainview for z/OS system programmer and the IAO will ensure that the TOP SECRET Facility Matrix Table is proper defined using the following example: **** BBI3 * FACILITY(USERxx=NAME=BBI3,PGM=BBM,ID=nn,ACTIVE,SHRPRF) FACILITY(BBI3=ASUBM,NOABEND,MULTIUSER,NOXDEF) FACILITY(BBI3=LUMSG,STMSG,SIGN(S),NORNDPW) FACILITY(BBI3=NOAUDIT,RES,WARNPW,NOTSOC) FACILITY(BBI3=MODE=FAIL,LOG(SMF,INIT,MSG,SEC9)) FACILITY(BBI3=UIDACID=8,LOCKTIME=000)

b
BMC Mainview for z/OS Resource Class must be defined or active in the ACP.
CM-4 - Medium - CCI-000336 - V-224613 - SV-224613r868741_rule
RMF Control
CM-4
Severity
Medium
CCI
CCI-000336
Version
ZMVZT038
Vuln IDs
  • V-224613
  • V-18011
Rule IDs
  • SV-224613r868741_rule
  • SV-33846
Failure to use a robust ACP to control a product could potentially compromise the integrity and availability of the MVS operating system and user data.
Checks: C-26296r868739_chk

Refer to the following report produced by the ACP Data Collection: - TSSCMDS.RPT(#RDT) If the BMC Mainview for z/OS Resource Class(es) is (are) defined in the Resource Definition Table (RDT) as follows, this is not a finding. RESOURCE CLASS = class RESOURCE CODE = X'hex code' ATTRIBUTE = MASK|NOMASK,MAXOWN(08),MAXPERMIT(044),ACCESS,DEFPROT ACCESS = NONE(0000),CONTROL(0400),UPDATE(6000),READ(4000) ACCESS = WRITE(2000),ALL(FFFF) DEFACC = READ

Fix: F-26284r868740_fix

The ISSO will ensure the BMC Mainview for z/OS resource class(es) is (are) defined in the TSS RDT. (Note: The RESCLASS and/or RESCODE identified below are examples of a possible installation. The actual RESCLASS and/or RESCODE values are determined when the product is actually installed on a system through the product's installation guide and can be site specific.) Use the following commands as an example: TSS ADDTO(RDT) RESCLASS(BMCVIEW) - RESCODE(3B) DEFACC(READ) - ATTR(MASK|NOMASK,DEFPROT,LONG,GENERIC) - ACLST(NONE,READ,UPDATE,ALL)

b
BMC MAINVIEW for z/OS configuration/parameter values are not specified properly.
AC-4 - Medium - CCI-000035 - V-224614 - SV-224614r519021_rule
RMF Control
AC-4
Severity
Medium
CCI
CCI-000035
Version
ZMVZT040
Vuln IDs
  • V-224614
  • V-18014
Rule IDs
  • SV-224614r519021_rule
  • SV-37808
BMC MAINVIEW for z/OS configuration/parameters controls the security and operational characteristics of products. If these parameter values are improperly specified, security and operational controls may be weakened. This exposure may threaten the availability of the product applications, and compromise the confidentiality of customer data.
Checks: C-26297r519019_chk

Refer to the Configuration Location dataset and member specified in the z/OS Dialog Management Procedures for BMC MAINVIEW for z/OS. Automated Analysis Refer to the following report produced by the z/OS Data Collection: - PDI(ZMVZ0040) The following keywords will have the specified values in the BMC MAINVIEW for z/OS security parameter member: Statement(values) ESMTYPE(AUTO|TSS)

Fix: F-26285r519020_fix

The BMC MAINVIEW for z/OS Systems programmer will verify that any configuration/parameters that are required to control the security of the product are properly configured and syntactically correct. Set the standard values for the BMC MAINVIEW for z/OS security parameters for the specific ACP environment along with additional IOA security parameters with standard values as documented below. Statement(values) ESMTYPE(AUTO|TSS)